vLoc-9800

 

          The vLoc-9800 is the updated version of the popular legacy 9860XT and 9890XT locators. Now with updated modern technology we have combined the best of both legacy locators into the vLoc9800.

The vLoc-9800 provides simplicity and fast performance with distance sensitive Left/Right Guidance™ and full automatic gain with the option to switch to manual. Single pushbutton depth and current is available on three active frequencies of 982Hz, 9.82kHz, and 83.1kHz. With the optional A-Frame pinpoint cable faults with directional arrows.

                     

                                                                                      

                                                                                                                                           

  The vLoc-9800’s 3.5”/89mm Tian-Ma TFT ¼ VGA full color display shows the ultra-fast response with left/right arrow indicators while in autogain mode or peak locate bar graph with numeric value in manual gain mode.

                                                                       

The vLoc-9800 5 Watt kit provides versatility with low frequencies for the telecom, power, and CATV industries as well as higher frequencies for the gas, water and sewer industries.

 

 
Features
  • Sonde locate mode

  • Customizable start-up screen

  • Backlit 3.5”/89mm color display

  • Alkaline and rechargeable operation

  • Sheath fault locate with accessory a-frame

  • Pushbutton depth and current measurement

  • Rechargeable Li-Ion with 40 hours of run time and back up alkaline battery

     


The Loc-10Tx high power transmitter is designed to provide customers the best choice when selecting and deciding on a professional locating system.

                                                                                                                                                      

 
Accessories

The A-frame fault finding accessory is used to detect ground faults on pipes and cables. In the case of pipes, the faults consist of coating defects. In the case of cables, faults are usually caused by insulation damage allowing the metallic sheath (or internal conductor) to become in contact with the ground.

A-frame Data Sheet VXMT Eng V2.3(Publish) 20150305.pdf
A-frame User Guide VXMT Eng V1.0 (Publish) 20140506.pdf

Induction Clamp is used to apply the transmitter signal to a pipe or cable when it is not possible or convenient to use the direct connection leads.

2'' (50mm) diameter clamp

VM-CLAMP Data Sheet VXMT Eng V2.6(Publish) 20150305.pdf
Clamp User Guide VXMT Eng V1.1 (Publish) 20140729.pdf

The plastic non-conductive extension rods have both male and female threads at opposite ends to screw together and extend the length. With the signal clamp attached to the extension rod it can now be safely used on overhead lines and lines in trenches or manholes.

VM-CLAMP Data Sheet VXMT Eng V2.6(Publish) 20150305.pdf
Clamp User Guide VXMT Eng V1.1 (Publish) 20140729.pdf

Sondes are battery powered transmitters used to trace the path of both non-metallic and metallic pipes and ducts. A receiver in sonde mode tuned to the same frequency can locate the position and depth of to the sonde.

•   Dimension: 0.7in (18mm) x 2.48in (63mm) long

•   Frequency: 33 kHz

•   Range: 15ft (4.5m)

•   Battery: 2 x button cell batteries

•   End cap: eyelet, 10mm studded

Note that sondes are only compatible with receivers that have matching sonde frequencies.

vLoc-9800 receiver is compatible with 9 kHz and 83 kHz Sondes.

vLocCam2 and VM-540 receiver is compatible with 512Hz, 640Hz and 33 kHz Sondes.

vScan receiver is compatible with 33 kHz Sondes.

VM-810 receiver is compatible with 83 kHz Sondes.

VM-850 receiver is compatible with 9 kHz Sondes.

The Spar unit works only with sondes under 10kHz.

Sonde Data Sheet VXMT Eng V2.3(Publish) 20150615.pdf
Sonde User Guide VXMT Eng V1.1 (Publish) 20140725.pdf

The live Cable Connector is usable on live cables up to 480 V ac 60/50Hz. The Live Cable Connector operates on frequencies of 8kHz, 33kHz and SIS.  Note that the Live Cable Connector should only be used by approved operatives adhering to company regulations and work practices while using appropriate safety equipment and clothing. 

Live Cable Connector Data Sheet VXMT Eng V1.0(Publish) 20150313.pdf

The LPC separation filter is used to safely inject a locate frequency onto a live cable via a domestic power socket to trace the services from the building to the connection in the street. It is suitable for connecting to voltages between 100V AC and 250V AC.

LPC Separation Filter Data Sheet VXMT Eng V2.4(Publish) 20170224.pdf
LPC User Guide VXMT Eng V1.1(Publish) 20170224.pdf

Manage a fleet of utility locators with the free MyLocator2 desktop application. Configure a fleet of locators by turning on or off features, selecting which frequencies the user has access to and creating custom start-up screens. The MyLocator2 software also will transfer data from the locator to a host computer, perform firmware updates and save the receivers configuration and settings.

When the receiver is connected to a computer running the MyLocator2 software, the software will automatically search our database for the latest software for both the receiver and desktop application. The receiver connects to the computer running MyLocator2 by the USB cable supplied with the receiver.

  • Add a splash start screen to the receiver
  • Perform firmware updates for the receiver 
  • Transfer data from the receiver to a laptop or PC

 

Direct Connection Leads are used to apply the transmitters signal onto the targeted pipe or cable. The leads consist of a plug, which plugs into the transmitter and a red "hot" lead and a black "ground" lead. Direct connection leads are fitted with various size and types of insulated clips for different applications.

Standard Clip version is suitable for day-to-day normal usage.

 

Heavy Duty Clip version is more suited for the gas and water industries where the size of the targeted lines are larger and connections will be made to bell housings, fire hydrants and transformer boxes. The more aggressive teeth of the heavy duty clip also make it easier to connect to objects that are painted such as hydrants.

 

Telco Clip version is suitable for telephone cable where the user cannot access the sheath of the cable. The "bed of nails" part of this clip can be clamped onto a cable breaking the insulation allowing contact with the sheath.

Ground Extension Spool is used to extend the ground connection to a suitable grounding position. Extending the ground allows the user to move the ground lead to various positions to help the transmitters signal to travel further. By extending the length of the ground lead the user can use locate tactics as performing a double ended connection.

Loc-5STx and Loc-5DTx 5 Watt Li-ion Battery Kits comes with a charger, power cable and Li-ion battery. The battery life with rechargeable battery is 30 hours at 1 watt and 6 hours at 5 watt output.

Charge the receivers internal Lithium-ion battery with a Receiver Vehicle Charging Lead. This 12ft/4m lead makes it easy to stay charged up while on the go.

Induction Clamp is used to apply the transmitter signal to a pipe or cable when it is not possible or convenient to use the direct connection leads.

4'' (100mm)diameter clamp


VM-CLAMP Data Sheet VXMT Eng V2.6(Publish) 20150305.pdf
Clamp User Guide VXMT Eng V1.1 (Publish) 20140729.pdf

Induction Clamp is used to apply the transmitter signal to a pipe or cable when it is not possible or convenient to use the direct connection leads.

5'' (125mm)diameter clamp

VM-CLAMP Data Sheet VXMT Eng V2.6(Publish) 20150305.pdf
Clamp User Guide VXMT Eng V1.1 (Publish) 20140729.pdf

 

Induction Clamp is used to apply the transmitter signal to a pipe or cable when it is not possible or convenient to use the direct connection leads.

18'' Flexible clamp

VM-CLAMP Data Sheet VXMT Eng V2.6(Publish) 20150305.pdf
Clamp User Guide VXMT Eng V1.1 (Publish) 20140729.pdf